| Polyisocyanurate (PIR) | 0.020–0.026 | 30–40 | 120–200 | Traps low-conductivity gas in a rigid cellular structure, reducing heat flow through the floor. | Ground floors, floors above unheated spaces, suspended floors, and retrofit systems where space is limited. | High thermal performance at relatively low thickness; joints should be tightly fitted and protected from moisture and damage. |
| Phenolic Foam | 0.020–0.025 | 35–45 | 100–150 | Uses a fine closed-cell structure to slow conduction and limit air movement within the board. | Thin floor build-ups, ground floors, and floors requiring a high level of thermal resistance. | Very low λ-values; board edges and surface facings must be considered when detailing joints and moisture control. |
| Extruded Polystyrene (XPS) | 0.029–0.036 | 28–45 | 200–700 | Closed-cell foam resists heat transfer and absorbs relatively little water compared with open-cell materials. | Concrete ground floors, floors exposed to intermittent moisture, perimeter zones, and inverted or heavily loaded floor assemblies. | Good moisture resistance and high compressive strength; performance depends on long-term loading and board thickness. |
| Expanded Polystyrene (EPS) | 0.031–0.038 | 15–35 | 70–200 | Small air-filled beads reduce conduction while the rigid board limits convection within the insulation layer. | Ground-bearing floors, floors above garages or unheated rooms, and general-purpose floor insulation. | Lightweight and economical; select an appropriate grade for the expected permanent and temporary loads. |
| Mineral Wool Floor Board | 0.035–0.040 | 100–180 | 30–80 | Interlocking mineral fibres trap air and reduce conduction, while also helping absorb airborne and impact sound. | Timber floors, floors above unheated spaces, acoustic floor systems, and cavity-filled suspended floors. | Strong acoustic and fire-resistance characteristics; requires protection from persistent moisture and careful support detailing. |
| Rigid Wood-Fibre Board | 0.038–0.040 | 110–250 | 100–200 | Compressed wood fibres create a porous structure that slows heat transfer and contributes to moisture buffering. | Suspended timber floors, floors in breathable construction, and renovation projects using natural-fibre materials. | Heavier than polymeric foams; moisture exposure, edge support, and structural loading must be assessed in the design. |
| Foil-Faced Rigid Foam Board | 0.020–0.035 | 30–45 | 100–250 | The foam core provides the main insulation, while the facing can reduce radiant heat transfer and act as a vapour-control layer when correctly sealed. | Solid floors, suspended floors, and floors where a continuous vapour-control layer is required. | Reflective foil does not replace the foam’s thermal resistance; any vapour-control function depends on sealed laps, joints, and penetrations. |
| How to read the λ-value: Lambda (λ) measures thermal conductivity. A lower value indicates better insulation performance for the same thickness. The approximate thermal resistance of a 100 mm layer is calculated as thickness ÷ λ; for example, λ = 0.025 W/m·K gives approximately R = 4.0 m²·K/W. Actual design values should use the declared product data, installation conditions, moisture exposure, joints, thermal bridges, and applicable building regulations. |